Product Description
Those who can control the temperature with the highest precision can also redefine precision time and time again. The control system of the Memmert CO2 incubator ICOmed is so finely tuned that the appliance reaches the setpoint temperature very quickly and without temperature overshoots. Alarm notifications to your mobile phone guarantee the safety of the chamber load, and the battery-buffered ControlCOCKPIT ensures continuous CO2 control even when there is a power failure. Ideal hygiene is a given too: rounded edges enable easy and thorough cleaning, the interior can be sterilised within 60 minutes at 180 °C.
Unrivalled user friendliness
All parameters can be set easily and intuitively both with the operating display and the ControlCOCKPIT or the AtmoCONTROL software. The shutter box can be opened, allowing fast access to controls. Maintenance is possible even if the appliances are stacked. The incubator ICOmed has USB and Ethernet connections as well as a data logger with a ten-year storage capacity. Data can be read and programmes can be uploaded by remote access. Numerous features of the CO2 incubator ICOmed don’t let anything open to be desired:
- Two gas connections with quick release connectors for automatic switch-over of gas bottles
- Electropolished, seamlessly welded chamber
- Electronic control for active humidification and dehumidification (40 to 97 % rh)
- Control of oxygen concentration by introducing nitrogen, adjustment range from 1 % to 20 % O2
CO2 Incubator ICOmed
Model sizes/Description | 50 | 105 | 150 | 240 | ||||
---|---|---|---|---|---|---|---|---|
Volume, approx. l | 56 | 107 | 156 | 241 | ||||
Width, (A) mm | 400 | 560 | 600 | |||||
Height, (B) mm | 425 | 480 | 700 | 810 | ||||
Depth (less 35 mm for fan), (C) mm | 330 | 400 | 500 | |||||
Max. number of perforated shelves | 5 | 6 | 10 | 12 | ||||
Max. loading per perforated shelf, kg | 15 | |||||||
Max. loading of chamber, kg | 75 | 90 | 120 | 140 | ||||
Width, (D) mm | 559 | 719 | 759 | |||||
Height (variable through adjustable feet), (E) mm | 795 | 850 | 1070 | 1180 | ||||
Depth (without door handle, depth of door handle 56 mm), (F) mm | 521 | 591 | 691 | |||||
Fully insulated heated stainless steel door | ||||||||
Additional heated inner glass door | ||||||||
Stainless steel shelves, perforated | 1 | 2 | ||||||
Stainless steel water dish (not applicable with option K7) | 1 | |||||||
Works calibration certificate (measuring point chamber centre) at +37 °C, 5 % CO2 for standard units | ● | |||||||
Works calibration certificate at 37 °C, 5 % CO2, 90 % rh and 10 % O2 (requires option K7 and option T6); standard equipment for units with O2 control | ● | |||||||
Works calibration certificate at 37 °C, 5 % CO2 and 90 % rh (requires option K7); standard equipment for units with active humidity control | ● | |||||||
CO2 connection set: hose with coupling and clamp | ● | |||||||
Standard sterilisation programme (without removing the sensors), humidity and CO2 sensor sterilised inside the CO2 incubator | 60 minutes at 180 °C | |||||||
Membrane filter (in order to remove impurities and pollutants, all incoming gases pass througha membrane filter before they reach the chamber) | ● | |||||||
Working temperature range, °C | at least 5 above ambient temperature up to+50 | |||||||
Setting temperature range, °C | +18 to +50 | |||||||
Setting accuracy, °C | 0.1 | |||||||
Temperature fluctuations with time at 37 °C (to DIN 12880:2007-05), K | +/- 0.1 | |||||||
Temperature variation in chamber at + 37 °C (to DIN 12880:2007-05), K | +/- 0.3 | |||||||
Humidity limitation thanks to a Peltier element; when waterdish is full and inserted, the Peltierelement limits the value of relative humidity in the interior to 93 % rh +/- 2.5 % | ● | |||||||
Setting range active humidity control (with option K7), % rh | 40 to 97 and rh-Off | |||||||
Setting accuracy, % rh | 0.5 | |||||||
Digital electronic CO2control with dual beam NDIR system, with auto-diagnostic system andacoustic fault indication, barometric pressure compensation | ● | |||||||
Setting range CO2, % CO2 | 0 to 20 | |||||||
Variation in time CO2, % CO2 | +/- 0.2 | |||||||
Setting accuracy CO2, % CO2 | 0.1 | |||||||
Setting range O2, % O2 | 1 to 20 | |||||||
Setting accuracy O2, % O2 | 0.1 | |||||||
Electrical load at 230/115 V, 50/60 Hz, approx. W | 1100 | 1300 | 1500 | 1650 |